electricity and gas and air for most TRUMPF MACHINES
the GAS needed to CO2 laser is
HE 4.6 – CO2 4.5 – N2 5.0 at 5 bar in to laser
.
cutting gas
O2 QUALITY 3.5 min 10-15 bar
N2 QUALITY 5,0 min 25-30 bar at hi flow 60m3/min
.
COMPRESSED AIR MIN 7 bar clean air, no olie or water in air
.
Electric
Old machines coming from europe need 380 volt at 50 hz tolerance +-5%
Newer machines coming from europa need 400 volt at 50 hz tolerance +-5%
New machines coming from europa need 420 volt at 50 hz tolerance +-5%
In asia and other country is transformer needed to compensate voltage and 60 hz
apr fuse needed according to laser power but confirm in the manuals
laser 1,5 kw 80 amp
laser 2,2 kw 100 amp
laser 3,2 kw 125 amp
laser 4,0 kw 160 amp
laser 5,0 kw 160 amp
laser 6,0 kw 200 amp
LASER TO BE USED AT 60 HZ MUST BE UPDATED TO OTHER POWER
IN some places you need power stabilizer as the electric coming into the factory is not stabile, if there is no stabile power the laser become unstable and make many problems and also cutting problem